How it works
A vertical turbine pump hangs one or more impeller bowls below the liquid surface, driven by a lineshaft from a motor above. Because the impellers are submerged, suction conditions are rarely the limit. A horizontal split case pump uses a double-suction impeller in a casing split along the shaft line, so the top half lifts off for maintenance and the axial thrust is largely balanced.
Where it fits
- Raw water intakes, wells and wet wells (vertical turbine)
- Cooling water and condenser duties
- Municipal water distribution and booster stations (split case)
- Large flows where maintenance access matters
Where it does not
- Long vertical turbine shafts need careful alignment and bearing care.
- Split case pumps take more floor space than an end suction pump of the same flow.
- Both are usually sized for a specific system. Running far from the design point shortens their life. See running off the curve.
Who makes the vertical turbine and split case pumps we supply
- American MarshSelf-priming, split case and vertical turbine pumps for water, municipal and general industrial duty. All territories
- AuroraSplit case and general industry pumps. MD, DC, DE
- FairbanksHeavy-duty vertical turbine and split case pumps. MD, DC, DE
What to send for a quote
- The liquid, its temperature, and any solids or chemicals in it
- The flow and pressure (or head) you need
- What it is replacing, with the nameplate if there is one
- How it runs: continuous, batch or standby, and anything that has failed before
Frequently asked questions
Vertical turbine or submersible pump?
A vertical turbine keeps the motor above the liquid, where it is easy to reach. A submersible puts the motor in the liquid, which suits deep or awkward sumps but means pulling the pump to service the motor.
Why choose a split case pump?
For large flows with low NPSH required, balanced thrust, and maintenance without disconnecting the suction and discharge piping.