How it works
Liquid is trapped between the gear teeth and the casing and carried round to the discharge, where the meshing teeth push it out. Each revolution moves a fixed volume, so flow follows speed closely and changes little with pressure. That is what makes a gear pump good for metering.
Where it fits
- Metering and dosing chemicals
- Viscous liquids such as resins, oils and polymers
- Corrosive liquids, in Liquiflo's corrosion-resistant materials
- Hazardous liquids, using a magnetic drive with no shaft seal
Where it does not
- Tight clearances do not tolerate abrasive solids.
- Like any positive displacement pump, it must not run against a closed discharge without a relief valve.
- The liquid lubricates the gears and bearings, so dry running damages them. A power monitor trips the motor on low load.
Who makes the gear pumps we supply
- LiquifloMag-drive and sealed gear pumps in corrosion-resistant materials. All territories
What to send for a quote
- The liquid, its temperature, and any solids or chemicals in it
- The flow and pressure (or head) you need
- What it is replacing, with the nameplate if there is one
- How it runs: continuous, batch or standby, and anything that has failed before
Frequently asked questions
Gear pump or centrifugal pump?
A gear pump holds a steady flow as pressure changes and handles viscous liquids well. A centrifugal pump is usually better for large flows of thin liquids at moderate pressure.
Why use a mag-drive gear pump?
A magnetic coupling drives the gears through a sealed shell, so there is no shaft seal to leak. It suits hazardous, toxic and expensive liquids.