NPSH explained: how to calculate NPSH available

Short answer

Net positive suction head available (NPSHa) is how much pressure, above the liquid's vapor pressure, pushes liquid into the pump, expressed in feet of head. Work it out as the absolute pressure on the liquid surface, plus the height of the liquid above the pump centerline, minus friction in the suction line, minus the vapor pressure, all converted to head. It must exceed the NPSH the pump requires (NPSHr) with margin, or the pump cavitates.

Worked example: water from an open tank

TermAt 68°FAt 180°F
Atmospheric pressure, as head (14.7 psia x 2.31 / specific gravity)+34.0 ft+35.0 ft
Liquid surface above pump centerline+10.0 ft+10.0 ft
Friction loss in the suction line−3.0 ft−3.0 ft
Vapor pressure, as head (0.34 psia cold, 7.5 psia hot)−0.8 ft−17.9 ft
NPSH available40.2 ft24.1 ft

The formula

NPSHa = Ha + Hs − Hf − Hvp

  • Ha: absolute pressure on the liquid surface, as head. For an open tank that is atmospheric pressure. For a closed vessel, use the vessel's absolute pressure.
  • Hs: height of the liquid surface above the pump centerline. It is negative when the pump lifts from below.
  • Hf: friction losses in the suction pipe, fittings, valves and strainer at the flow you are checking.
  • Hvp: the liquid's vapor pressure at the pumping temperature, as head.

Convert pressure to head with: feet = psi x 2.31 / specific gravity. Use absolute pressures throughout.

What the worked example shows

The same tank, pipe and pump lose about 16 feet of NPSHa when the water is hot, because vapor pressure climbs steeply with temperature. Hot condensate, boiler feed and liquids near their boiling point are where NPSH problems show up first. Altitude matters too: atmospheric head falls by roughly a foot for every 1,000 feet of elevation.

What NPSHr means

NPSHr (NPSH required) is printed on the pump curve and rises as flow rises. It is measured as the point where the pump has already lost 3% of its head to cavitation, so it is not a safe operating limit. A pump running with NPSHa equal to NPSHr is already cavitating.

How much margin to leave

There is no single figure. The Hydraulic Institute's guidance (ANSI/HI 9.6.1) recommends a margin ratio of NPSHa to NPSHr that depends on the application, from about 1.1 for many general duties up to 2 or more for high suction energy pumps and critical services. Check the margin at the highest flow the pump will see, not only at the design point.

If the margin is too small

  • Raise the liquid level or lower the pump.
  • Shorten or enlarge the suction line and remove unnecessary fittings.
  • Keep suction strainers clean and suction valves fully open.
  • Cool the liquid, or pressurize the vessel, if the process allows.
  • Reduce the flow, or slow the pump with a variable frequency drive. NPSHr falls as flow falls.
  • Choose a pump with a lower NPSHr, such as a larger, slower pump or one with an inducer.

See pump cavitation for the symptoms, and hydraulic system analysis when you want the options compared before anything is changed.

Frequently asked questions

What is the difference between NPSHa and NPSHr?

NPSHa is what the system supplies to the pump. NPSHr is what the pump needs at a given flow, from the manufacturer's curve. NPSHa must be the larger, with margin.

Can NPSH available be negative?

Not in practice. If the calculation gives zero or less, the liquid would boil in the suction line before it reached the pump.

Does NPSH apply to positive displacement pumps?

Yes, though it is often stated as net positive inlet pressure (NPIP). Reciprocating pumps also need an allowance for acceleration head, because the liquid in the suction line speeds up and slows down on every stroke.

Why does NPSHa change with flow?

Friction in the suction line rises with flow, so NPSHa falls as flow rises while NPSHr climbs. The two lines meet at the flow where cavitation begins.

Products and services that help

Written by the Southern Design reliability team. Last reviewed October 2026.

CallRequest a quote