Pump down? Call 877-917-8677 Customer portal sign in
SOUTHERN DESIGNRedefining Reliability

Stop fixing the same pump twice.

Southern Design supplies pumps, mechanical seals and valves, and the reliability engineering that finds out why they fail. For process plants and water utilities in Arkansas and the Mid-Atlantic.

  • Over 20 years in industrial service
  • 33 manufacturers represented
  • Offices in El Dorado, AR and Millersville, MD
Pump P-204B, 36 months of history Illustrative example
Seal replaced. Again. Root cause found: running off its curve 18 months, no failures
  • Seal replaced, five times
  • Root cause found
  • 18 months, no failures

Replacing the seal five times treats the symptom. One root cause analysis ends the pattern. That is the difference between a parts supplier and a reliability partner.

What brought you here today?

I need a pump, seal or valve

Send us the application or the part number. We size it, quote it and tell you the lead time.

Request a quote

I have a pump that keeps failing

We troubleshoot on site, run the root cause failure analysis and tell you what to change, not just what to replace.

Book a troubleshooting visit

I need a repair

Precision repair for pumps and rotating equipment, including mag-drive and sealed pumps, plus mechanical seal repair and exchange programs.

Arrange a repair

Common pump problems, and what fixes them

Plain answers to the failures that cost plants the most.

  • Mechanical seal keeps failingA pump seal that fails again and again is reacting to dry running, a failed flush, shaft movement or the wrong materials. How to read the seal and fix it.
  • Pump cavitationCavitation sounds like gravel in the pump and destroys impellers, seals and bearings. The signs, the causes on the suction side, and the fixes that work.
  • NPSH calculationNPSHa is atmospheric head plus static head, minus friction and vapor pressure. The formula, a worked example, what NPSHr means and how much margin to leave.
  • Pump running off its curveA pump run far from its best efficiency point bends its shaft and wears out seals and bearings. How to find the operating point and bring it back.
  • Pump bearings failing earlyPump bearings rarely wear out. They fail from contaminated or wrong lubricant and from loads they were not chosen for. What the bearing and the oil tell you.
  • Calculating pump MTBFPump MTBF is pumps in service times months, divided by failures. A worked example, what counts as a failure, and how to find the few pumps eating the budget.
  • Water hammer and pulsationBanging pipes, swinging gauges and broken supports come from water hammer or pump pulsation. What causes each and how dampeners, valves and drives fix them.
  • Mag-drive pump failuresMagnetic drive pumps have no seal to leak, but they fail from dry running, low flow, decoupling and solids. How to recognize each and protect the pump.
  • Repair or replace a pumpRepair a pump that suits its duty and has a fixable cause. Replace one that is wrong for the job or costs too much to keep. Five questions that decide it.
  • Setting up a reliability programA pump reliability program is a list of what you have, a record of every failure and its cost, and root cause work on the worst pumps. Seven steps to start.

The line card, in plain sight

Every manufacturer we represent, with what they make. Pick a category, find the name on your nameplate, and ask us for a price.

Large industrial pumps installed in a plant room
  • American MarshSelf-priming, split case and vertical turbine pumps for water, municipal and general industrial duty. All territories
  • AplexHigh-pressure reciprocating pumps built to withstand harsh conditions. MD, DC, DE
  • AuroraSplit case and general industry pumps. MD, DC, DE
  • EbaraHeavy-duty dewatering and submersible sump pumps. AR
  • FairbanksHeavy-duty vertical turbine and split case pumps. MD, DC, DE
  • Finish ThompsonANSI-dimensional ETFE-lined mag-drive pumps, plus FTI Air air-operated double diaphragm pumps. All territories
  • GracoElectric and air-operated diaphragm pumps and peristaltic pumps, including the Graco Quantm electric diaphragm range. All territories
  • HiscoANSI centrifugal pumps, including parts to fit Goulds, Flowserve and Summit pumps, plus self-priming trash pumps. All territories
  • John CraneMechanical seals and seal support systems. MD, DC, DE
  • LiquifloMag-drive and sealed gear pumps in corrosion-resistant materials. All territories
  • LotusCustom-engineered bottom, top and side-entry industrial mixers. MD, DC, DE
  • MyersGeneral-duty submersible and self-priming pumps. MD, DC, DE
  • NomadAftermarket air-operated diaphragm pumps and parts. All territories
  • PPCMetal bellows, split and pusher mechanical seals. All territories
  • RichterPFA-lined mag-drive and sealed pumps with solids-handling capability, plus PFA-lined control, relief and sampling valves. All territories
  • SulzerPumps, agitators, mixers and separators. AR
  • ToshibaElectric motors, drives and control panels. All territories
  • WEGElectric motors, variable frequency drives and soft starters. All territories
  • U.S. Seal Mfg.Component mechanical seals supporting a wide range of pump applications. All territories

Lines differ by territory; the states are shown beside each name. Do not see the brand you run? Ask us anyway, or browse products by type.

Know what every pump is costing you

Our Reliability Management System gives contract customers one record for every piece of rotating equipment, and a reliability engineer who works the list with you.

  • An accurate database of your pumps and rotating equipment
  • MTBF, downtime cost, repair material and labor cost, reported per machine
  • Root cause analysis tracked from failure to fix
  • A lead reliability engineer assigned to your plant
  • Technical documents in one place
  • Parts interchangeability, so the storeroom carries less
  • Training for operations and maintenance, aimed where the data points
Bad actor reportSample data
EquipmentMTBF12-month cost
P-204BBlack liquor transfer4.1 mo
$48,2005 repairs
P-117ACooling water9.5 mo
$21,7502 repairs
P-330Caustic unloading11.2 mo
$14,3001 repair
P-052Boiler feed38 mo
$0No repairs

Cost is repair material plus labor plus downtime. The worst few machines usually carry most of the spend, so that is where the work starts.

Repair, field service and engineering

The same people who quote the part can fix it, install it and work out why the last one failed.

Lathe in a machine shop

Precision repair

Shop repair for a wide range of pumps and rotating equipment, with a failure report so you know what happened.

  • Mechanical seal repair and exchange programs
  • Mag-drive and sealed pump repair
  • Root cause failure analysis and reporting
Technician in protective gear working from a tool case on site

Field service

Technicians at your site, by the day or for the whole job.

  • Maintenance by the day or full turnkey
  • Equipment installation
  • On-site performance troubleshooting
Engineer marking up technical drawings at a desk

Engineering and design

Computer hydraulic simulation of your pumping and piping system, before you buy or when something is not performing.

  • System design and equipment selection
  • Troubleshooting pumping and piping systems
  • Reliability optimization
Close-up of machine gears

Lubrication training and audits

ICML training for your team, and a plant walk-through that benchmarks your lubrication program against industry standards.

  • MLA I and II, MLT I and II courses
  • Plant lubrication audits
  • Lubrication analysis and upgrade recommendations

Built around the plant you run

  • ChemicalCorrosive and hazardous service. Lined mag-drive pumps, sealless designs and PFA-lined valves.
  • Pulp and paperMechanical seals, seal water control and repair programs for stock and liquor service.
  • Water and wastewaterSplit case, vertical turbine and submersible pumps, with automatic control valves.
  • Power generationMotors, drives and condition monitoring for critical rotating equipment.
  • PharmaceuticalDiaphragm and peristaltic pumps for transfer and metering.
  • SteelHeavy-duty pumps and lubrication programs for harsh, continuous duty.
  • Bio-energyPump selection, sealing and field service for process and utility systems.
  • Food and beverageHygienic transfer and metering pumps, sanitary seals and washdown-ready equipment.
Stainless steel process piping, valves and pumps in a plant

Results from plants like yours

Engineers buy on evidence. This section holds three short case studies with real numbers.

Case study needed from Southern Design

A repeat seal failure, solved

Plant type
To confirm
MTBF before and after
__ months to __ months
Annual cost avoided
$__
Case study needed from Southern Design

A plant-wide RMS rollout

Plant type
To confirm
Machines tracked
__
Repair spend, year one against year two
$__ to $__
Case study needed from Southern Design

A municipal pump replacement

Utility
To confirm
What was specified
To confirm
Outcome
To confirm

Find the specialist for your state

Arkansas

Corporate office
2710 North West Avenue
El Dorado, AR 71730
(870) 725-2588
Pumps, seals and repair in Arkansas

Maryland, DC and Delaware

East Coast office
8229 Cloverleaf Drive, Suite 430
Millersville, MD 21108
877-917-8677
Pumps, seals and repair in MD, DC and DE

Virginia and the Carolinas

Regional specialists
Covering Virginia, North Carolina and South Carolina
877-917-8677
Pumps, seals and repair in VA, NC and SC

What happens after you get in touch

  1. You tell us the problemA part number, an application, or a machine that will not stay running.
  2. A specialist calls you backSomeone who knows pumps, from the office that covers your state.
  3. We quote or diagnoseSized and priced with a lead time, or a site visit to find the cause.
  4. We supply, repair and track itContract customers see every repair and its cost in RMS.

Tell us what you need

Six fields. It goes to the specialist for your state, not a general inbox.

877-917-8677

That is 877-91-PUMPS. Call if equipment is down.

  • Quotes for pumps, seals, valves and motors
  • Repair and seal exchange
  • Troubleshooting and root cause analysis
  • Reliability assessments and RMS
  • Lubrication training and audits
How urgent is it?
We reply within one working day. Sooner if equipment is down.
CallRequest a quote